The molecular sieve, also known as synthetic zeolite, is a synthetic zeolite: a crystalline aluminosilicate with pores of uniform size, from 3 to 10 Å depending on the type. These pores work as a molecular-scale filter: molecules smaller than the pore, such as water, enter and are retained, while larger ones pass by.
That is why molecular sieve dries gases and liquids down to dew points of −70 °C or lower, far beyond what silica gel or clay can achieve, and it keeps its capacity even when humidity is very low or temperature is high. In this guide you will see the types that exist, what each one is for and how to choose it. If you already know what you need, see our molecular sieve 3A, 4A, 5A and 13X.
Index
Types of molecular sieve
| Type | Pore | What it adsorbs | Applications | Formats at YDRY |
|---|---|---|---|---|
| 3A | 3 Å | H₂O, NH₃. Does not retain ethanol, methanol or CO₂ | Insulating glass, dehydration of ethanol and methanol, cracked gases, refrigerants | Beads 0.25-1 mm Beads 1-2 mm Beads 2-3 mm |
| 4A | 4 Å | H₂O, CO₂, H₂S, SO₂, ethanol | General drying of gases, air, natural gas and solvents; desiccant in equipment and packaging | Beads 3-5 mm |
| 5A | 5 Å | H₂O, CO₂, CO, CH₄, N₂, linear n-paraffins | Hydrogen purification by PSA, n-paraffin separation, oxygen generators | Beads 1-3 mm |
| 13X | ≈10 Å | H₂O and CO₂ at the same time, H₂S, mercaptans, aromatic hydrocarbons | Air pre-purification, compressed air dryers, oxygen concentrators, desulfurization of LPG and natural gas | Beads 1-3 mm Beads 3-5 mm Beads 4-6 mm Pellets 1/8" (3 mm) |
Rule of thumb: the sieve retains molecules smaller than its pore. If the product you want to dry is a small, polar molecule, such as ethanol, choose the smallest pore that keeps that product out (3A) so it is not adsorbed along with the water.
Use in hydrogen purification (PSA)
- In hydrogen PSA units the bed combines several layers: activated alumina or silica gel for water, activated carbon for CO₂ and hydrocarbons and, at the end, 5A molecular sieve, which retains CO, N₂, CH₄ and residual CO₂.
- Hydrogen is barely adsorbed: its kinetic diameter is about 2.9 Å and its polarity is very low, so it passes through the bed and comes out at purities of up to 99.999%.
- The 13X sieve is used in the polishing stage for its high capacity for CO₂ and polar molecules, and it is also the usual adsorbent in oxygen concentrators.
- In PSA the bed is regenerated by lowering the pressure, with cycles of a few minutes, so the mechanical strength of the beads is key to prevent them from breaking or generating dust.
Regeneration
Molecular sieve is not used up: it is regenerated and reused for years. There are two ways to do it:
- By temperature (TSA): the bed is heated to 200-300 °C with a dry purge gas that carries away the desorbed water. It is the most complete regeneration and the one used in industrial dryers and natural gas pretreatment.
- By pressure (PSA): the pressure is lowered and the bed is purged with part of the already dry gas. It needs no heat and allows cycles of a few minutes, as in heatless compressed air dryers and hydrogen and oxygen units.
For small quantities, for example in a laboratory, an oven at 250-300 °C for 2-4 hours is enough, then let it cool in a closed container. Do not exceed 350 °C and avoid contact with liquid water while hot, because it damages the crystal structure and reduces capacity.
Selection criteria
What you want to retain and what not: 3A if the product is a small, polar molecule (ethanol, methanol, refrigerants); 4A for general drying; 5A to separate linear paraffins or purify hydrogen; 13X to remove moisture and CO₂ at the same time or large molecules.
Required dew point: below −40 °C molecular sieve is the right choice; for less demanding drying, activated alumina or silica gel may be enough and are cheaper.
Operating conditions:
Temperature: capacity drops as temperature rises; it adsorbs best below 50 °C.
Pressure: the higher the pressure, the greater the adsorption capacity.
Particle size: fine beads (0.25-2 mm) adsorb faster and suit small columns and filling insulating glass spacers; coarse beads (3-6 mm) reduce pressure drop in large beds.
Contaminants: oil and liquids block the pores. Protect the bed with a prefilter or a layer of activated alumina.
Key advantages
Very deep drying, down to dew points of −70 °C or lower.
Size selectivity: it retains water without retaining the product being dried.
Capacity at low humidity and high temperature, where other desiccants stop working.
Regenerable for thousands of PSA or TSA cycles.
Mechanical strength against abrasion and pressure and temperature changes.
Need molecular sieve for your process? At YDRY we supply 3A, 4A, 5A and 13X molecular sieve in 20 and 25 kg bags from Spain, with technical data sheet and volume pricing for pallet orders and recurring purchases. See all formats in our molecular sieve shop or tell us about your application by WhatsApp, email or phone, or book a meeting, and we will recommend the right type and particle size.
How many kilos do you need? Calculate the load of your dryer or column with our molecular sieve and activated alumina calculator: with the tower dimensions it gives you the kilos and bags, no email required.
Frequently asked questions
5A (5 Å pore): retains water, CO₂ and linear molecules such as n-paraffins, and lets branched ones through. It is the usual choice for hydrogen purification and paraffin separation.
13X (pore of about 10 Å): has the highest adsorption capacity, removes moisture and CO₂ at the same time and retains larger molecules such as H₂S and mercaptans. It is the usual choice in compressed air dryers and air pre-purification.
At TSA (thermal regeneration) the bed is heated, normally to between 200 and 300 °C, with a purge gas that carries away the desorbed water; it is the most complete regeneration, but it uses more energy. In PSA (pressure regeneration) the bed is depressurized and purged with part of the product gas, allowing short cycles of a few minutes. The choice depends on the process, the flow rate and the target dew point.
Used properly, a molecular sieve can work for several years. Its service life depends mainly on bead abrasion, the number and intensity of thermal cycles and the presence of contaminants (oil, liquids, heavy compounds) that block the pores. If the outlet dew point slowly rises, it should be checked or replaced.
Coarse beads (3-6 mm, about 4-8 mesh) cause less pressure drop and suit high flow rates; fine beads (1-3 mm, about 8-12 mesh) adsorb faster and shorten the mass transfer zone, at the cost of higher pressure drop. In existing equipment, the particle size is usually set by the manufacturer. For insulating glass, 0.25-2 mm beads are used.
Yes, it is a common configuration: a first layer of activated alumina retains most of the moisture and protects the bed from droplets and contaminants, and then a layer of molecular sieve does the fine adsorption down to very low dew points. This mixed bed extends the life of the sieve.
The silica gel has more capacity when humidity is high and is cheaper, so it is the usual choice to protect products in packaging and containers. Molecular sieve holds water much more strongly: it is better when humidity is low, when a very low dew point is needed or when drying at high temperature.
3A molecular sieve, in 1-2 mm beads or in 0.25-1 mm beads for narrow spacers. It retains the moisture of the air trapped between the panes without adsorbing argon or nitrogen, so the unit neither fogs up nor deforms. We explain it in detail in why insulating glass contains molecular sieve.