Molecular sieve for insulating glass: why it stops the glass from fogging

If you manufacture or install windows, you already know that the worst failure of insulating glass (also called double glazing or an insulating glass unit, IGU) is condensation appearing between the two panes. Once it happens, it cannot be cleaned: the unit has to be replaced. The part that prevents it is small and almost invisible: the molecular sieve inside the spacer bar.

Why insulating glass fogs up

When the unit is sealed, air is trapped between the panes, and that air contains water vapor. When the outside temperature drops, the inner surface of the cavity cools and the vapor condenses as droplets or mist. In addition, over the years a small amount of moisture enters through the seal.

The solution is to dry the air in the cavity and keep it dry for the whole life of the window. To do this, the spacer bar (the metal or plastic frame that separates the panes) is filled with a desiccant that adsorbs that vapor.

Why molecular sieve is used and not another desiccant

The molecular sieve is a synthetic zeolite with pores of uniform size. Compared with other desiccants it has three key advantages for this application:

  • It dries to very low humidity levels, so the dew point inside the cavity stays well below winter temperatures.
  • It holds water very strongly and does not release it when the glass warms up in the sun.
  • It is selective: type 3A has pores that let water in but not larger molecules, such as the argon or air that fill the cavity.

Which molecular sieve to use: 3A

For insulating glass, the usual choice is 3A molecular sieve. Its pore size (about 3 angstroms) adsorbs water but not nitrogen, oxygen or argon. If the desiccant adsorbed those gases, temperature changes would vary the pressure inside the cavity and the panes could deform slightly. In some cases blends of 3A with other desiccants are used; the choice depends on the spacer manufacturer and the sealing system.

At YDRY we have 3A molecular sieve for insulating glass in 0.25-1 mm beads, for narrow spacers and automatic filling, and in 1-2 mm beads, the standard format for double and triple glazing. It is supplied in 20 or 25 kg bags with volume pricing for manufacturers.

TypeApproximate poreUse in insulating glass
3A3 ÅThe standard: adsorbs only water
4A4 ÅAlso adsorbs some gases; less common in IGUs
13X10 ÅAdsorbs water and larger gases; used in specific blends

How it is applied in manufacturing

  • The hollow spacer bar is filled with molecular sieve beads, usually with an automatic filling machine.
  • The spacer has small perforations towards the cavity so the desiccant is in contact with the inside air.
  • The sieve must be kept dry and well packed until filling: if left open, it saturates with the workshop’s humidity and loses capacity before the unit is sealed.
  • The particle size is set by the machine and the spacer; it is worth confirming with the supplier.

What happens when the sieve saturates

If the seal fails or the desiccant saturated too early, moisture is no longer absorbed and condensation appears inside. That is why two things determine the service life of the window: the quality of the seal and the quantity and condition of the sieve at the time of assembly.

Do you manufacture insulating glass or spacer bars? Write to us or request a quote in the form and we will advise you with no obligation.

We help you choose the right molecular sieve and packaging format for your production line.

Frequently asked questions

Is molecular sieve the same as zeolite?

Yes, they are two names for the same material. In the glass industry it is also simply called “spacer desiccant”.

Can silica gel be used in insulating glass?

It has been used in blends, but silica gel holds water less strongly and does not dry to such low dew points. That is why the current standard is 3A molecular sieve.

How much molecular sieve does a window contain?

It depends on the size of the unit, the spacer and the manufacturer. The usual practice is to fill the spacer along its whole perimeter or the length indicated by the sealing system.